Pocivalnik, M; Pichler, G; Zotter, H; Tax, N; Müller, W; Urlesberger, B.
Regional tissue oxygen saturation: comparability and reproducibility of different devices.
J Biomed Opt. 2011; 16(5):057004
Doi: 10.1117/1.3575647
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
- Führende Autor*innen der Med Uni Graz
-
Pichler Gerhard
-
Ribitsch Mirjam
- Co-Autor*innen der Med Uni Graz
-
Höller Nina
-
Urlesberger Berndt
-
Zotter Heinz
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- UNLABELLED: Comparability and reproducibility of different near-infrared spectroscopy devices measuring regional tissue oxygen saturation remain poor. Aim of the present study was to compare values and reproducibility of cerebral∕peripheral "tissue-oxygenation-index" (TOI; NIRO 300, Hamamatsu(®), Japan) with cerebral∕peripheral "regional-oxygen-saturation" (rSO; INVOS5100, Somanetics(®), USA), and to analyze the influence of quality criteria. METHODS: cTOI and crSO2 were measured on the left forehead, pTOI and prSO2 were measured on the left calf. To analyse reproducibility, optodes were reapplied five times. A quality criterion was introduced for cTOI, crSO2 and prSO2. For pTOI quality criteria were introduced in combination with a venous occlusion technique. RESULTS: Cerebral measurements were performed in 37 neonates. cTOI (72.7+∕-6.2%) was lower than crSO2 (83.3+∕-5.8%) (p < 0.001). The mean difference between cTOI and crSO2 was 10%. Mean standard deviations of cTOI and crSO2 were similar (cTOI: 4.9+∕-3.6; crSO2: 4.5+∕-2.6). Peripheral measurements were performed in 39 neonates. pTOI (66.0+∕-7.9%) was lower than prSO2 (82.0+∕-7.0%)(p < 0.001). The mean difference between pTOI and prSO2 was 15%. Mean standard deviations of pTOI (3.7+∕-2.6%) were lower than of prSO2 (5.0+∕-3.0%) (p = 0.047). CONCLUSION: TOI values were significantly lower than rSO2 values, in cerebral and peripheral measurements. Reproducibility was higher for pTOI than for prSO2.
- Find related publications in this database (using NLM MeSH Indexing)
-
Cerebrovascular Circulation - physiology
-
Equipment Design - administration & dosage
-
Equipment Failure Analysis - administration & dosage
-
Humans - administration & dosage
-
Infant, Newborn - administration & dosage
-
Oximetry - instrumentation
-
Oxygen - blood
-
Photometry - instrumentation
-
Reproducibility of Results - administration & dosage
-
Sensitivity and Specificity - administration & dosage
-
Spectroscopy, Near-Infrared - instrumentation
- Find related publications in this database (Keywords)
-
tissue oxygenation index
-
rSO2
-
NIRO300
-
INVOS5100
-
comparability
-
reproducibility