Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Uzuner, N; Horner, S; Pichler, G; Svetina, D; Niederkorn, K.
Right-to-left shunt assessed by contrast transcranial Doppler sonography: new insights.
J Ultrasound Med. 2004; 23(11):1475-1482 Doi: 10.7863/jum.2004.23.11.1475
Web of Science PubMed FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
Horner Susanna
Niederkorn Kurt
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
OBJECTIVE: Simple diagnostic techniques such as contrast transcranial Doppler sonography (cTCDS) are popular for assessing a right-to-left shunt (RLS) because of their high sensitivity. In this study, we applied cTCDS to a large patient group with a patent foramen ovale, proved by contrast transesophageal echocardiography (TEE). METHODS: One hundred one patients with stroke, in whom a patent RLS had been shown on contrast TEE, were investigated by TCDS of both middle cerebral arteries. Injection of 10 mL of agitated saline was applied without and subsequently with the Valsalva maneuver (VM) at the beginning of the contrast agent injection, and then 10 mL of a galactose-based contrast agent was applied in the same protocol. RESULTS: In all patients, cTCDS with the galactose contrast agent showed an RLS when performed with VM, but it showed an RLS in only 59 patients without VM. In contrast, saline showed an RLS in 54 patients with VM and in 20 patients without VM. The differences in diagnostic sensitivity were statistically significant (P < .001). Eighteen patients had only 1 microembolic signal (MES) after galactose injection, whereas others had more. The mean (SD) arrival times of the MES were 9 (6) seconds (range, 1-51 seconds) after galactose injection with VM and 9 (3) seconds (range, 2-20 seconds) after agitated saline with VM. The differences were not significant. CONCLUSIONS: Contrast TCDS with VM shows a TEE-proven RLS with 100% sensitivity, but this was not true with galactose application without VM or agitated saline with or without VM. Therefore, use of the galactose contrast agent with VM is strongly recommended for detecting an RLS on TCDS. However, the arrival time and number of MESs detected need to be tested further.
Find related publications in this database (using NLM MeSH Indexing)
Adolescent -
Adult -
Child -
Contrast Media -
Echocardiography, Transesophageal -
Embolism, Paradoxical - etiology
Female - etiology
Heart Septal Defects, Atrial - ultrasonography
Humans - ultrasonography
Image Enhancement - ultrasonography
Male - ultrasonography
Middle Aged - ultrasonography
Polysaccharides - diagnostic use
Sensitivity and Specificity - diagnostic use
Statistics, Nonparametric - diagnostic use
Ultrasonography, Doppler, Transcranial - methods

Find related publications in this database (Keywords)
cerebrovascular disease
patent foramen ovale
sonography
transcranial Doppler sonography
© Med Uni Graz Impressum