Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Brader, P; Schoellnast, H; Deutschmann, HA; Thimary, F; Schaffler, G; Reittner, P.
Acute pulmonary embolism: comparison of standard axial MDCT with paddlewheel technique.
Eur J Radiol. 2008; 66(1):31-36 Doi: 10.1016/j.ejrad.2007.05.020
Web of Science PubMed FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Brader Peter
Co-Autor*innen der Med Uni Graz
Deutschmann Hannes
Reittner Pia
Schaffler Gottfried
Schoellnast Helmut
Thimary Felix
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
The purpose of this study was to evaluate the ability of rotated paddlewheel reformations for the detection of central and peripheral pulmonary embolism (PE) compared to standard axial multi detector CT (MDCT) images. CT scans of 35 patients with PE were reviewed by three independent readers for the detection of pulmonary emboli using standard axial CT scans and reformatted paddlewheel technique. All images were evaluated in random order. MDCT examinations were performed with a collimation of 1.25 mm, a pitch of six and a reconstruction interval of 0.8mm. For each patient MIP were reformatted by using a paddlewheel arrangement with 5mm slab thickness and 5 degrees rotation. Standard of reference for PE was a consensus reading of the axial images by all three readers. The overall sensitivity for the axial images for the three readers ranged between 91% and 96%; for paddlewheel reformations from 78% to 83%; the specificity for both methods was 98-99%. Inter- and intraobserver agreement was also higher for axial images than for paddlewheel reformations. Comparing standard axial MDCT scans and reformatted paddlewheel images no significant difference for the detection of central PE was found, whereas for the detection of peripheral emboli standard axial images showed a significant higher percentage of detecting PE than paddlewheel reformations.
Find related publications in this database (using NLM MeSH Indexing)
Acute Disease -
Adult -
Aged -
Aged, 80 and over -
Contrast Media -
Female -
Humans -
Iohexol - analogs & derivatives
Male -
Middle Aged -
Pulmonary Embolism - radiography
Retrospective Studies -
Sensitivity and Specificity -
Tomography, X-Ray Computed - methods

Find related publications in this database (Keywords)
computed tomography (CT)
angiography
computed tomography (CT)
maximum intensity projection
computed tomography (CT)
multi-detector row
embolism
pulmonary
pulmonary arteries
CT