Werner, P; Russo, M; Scherzer, S; Aref, T; Coti, I; Mascherbauer, J; Kocher, A; Laufer, G; Andreas, M.
Transcatheter Caval Valve Implantation of the Tricento Valve for Tricuspid Regurgitation Using Advanced Intraprocedural Imaging.
JACC Case Rep. 2019; 1(5):720-724
Doi: 10.1016/j.jaccas.2019.11.020
(- Case Report)
[OPEN ACCESS]
PubMed
FullText
FullText_MUG
- Co-Autor*innen der Med Uni Graz
-
Andreas Martin
-
Laufer Günther
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- A 75-year-old patient with previous mitral and tricuspid reconstruction experienced severe tricuspid regurgitation. On the basis of a prohibitive surgical risk, an interventional heterotopic tricuspid valve implantation was planned. Implantation was performed using fusion-imaging, which facilitated intraprocedural navigation. At 6-month follow-up, the patient presented in improved condition with reduced symptoms. (Level of Difficulty: Advanced.).