Müller, W; Lohman, TG; Stewart, AD; Maughan, RJ; Meyer, NL; Sardinha, LB; Kirihennedige, N; Reguant-Closa, A; Risoul-Salas, V; Sundgot-Borgen, J; Ahammer, H; Anderhuber, F; Fürhapter-Rieger, A; Kainz, P; Materna, W; Pilsl, U; Pirstinger, W; Ackland, TR.
Subcutaneous fat patterning in athletes: selection of appropriate sites and standardisation of a novel ultrasound measurement technique: ad hoc working group on body composition, health and performance, under the auspices of the IOC Medical Commission.
Br J Sports Med. 2016; 50(1):45-54 Doi: 10.1136/bjsports-2015-095641 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Müller Wolfram
Co-Autor*innen der Med Uni Graz
Ahammer Helmut
Anderhuber Friedrich
Fürhapter-Rieger Alfred
Materna Wilfried
Pilsl Ulrike
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Precise and accurate field methods for body composition analyses in athletes are needed urgently. Standardisation of a novel ultrasound (US) technique for accurate and reliable measurement of subcutaneous adipose tissue (SAT). Three observers captured US images of uncompressed SAT in 12 athletes and applied a semiautomatic evaluation algorithm for multiple SAT measurements. Eight new sites are recommended: upper abdomen, lower abdomen, erector spinae, distal triceps, brachioradialis, lateral thigh, front thigh, medial calf. Obtainable accuracy was 0.2 mm (18 MHz probe; speed of sound: 1450 m/s). Reliability of SAT thickness sums (N=36): R(2)=0.998, SEE=0.55 mm, ICC (95% CI) 0.998 (0.994 to 0.999); observer differences from their mean: 95% of the SAT thickness sums were within ± 1 mm (sums of SAT thicknesses ranged from 10 to 50 mm). Embedded fibrous tissues were also measured. A minimum of eight sites is suggested to accommodate inter-individual differences in SAT patterning. All sites overlie muscle with a clearly visible fascia, which eases the acquisition of clear images and the marking of these sites takes only a few minutes. This US method reaches the fundamental accuracy and precision limits for SAT measurements given by tissue plasticity and furrowed borders, provided the measurers are trained appropriately. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Find related publications in this database (using NLM MeSH Indexing)
Athletic Performance - physiology
Body Composition - physiology
Body Fat Distribution -
Female -
Health Status -
Humans -
Male -
Muscle, Skeletal - anatomy & histology
Muscle, Skeletal - diagnostic imaging
Observer Variation -
Sports - physiology
Subcutaneous Fat - anatomy & histology
Subcutaneous Fat - diagnostic imaging
Ultrasonography -