Sperzel, J; Dänschel, W; Gutleben, KJ; Kranig, W; Mortensen, P; Connelly, D; Trappe, HJ; Seidl, K; Duray, G; Pieske, B; Stockinger, J; Boriani, G; Jung, W; Schilling, R; Saberi, L; Hallier, B; Simon, M; Rinaldi, CA.
First prospective, multi-centre clinical experience with a novel left ventricular quadripolar lead.
EUROPACE. 2012; 14(3): 365-372.
Doi: 10.1093/europace/eur322
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
- Co-Autor*innen der Med Uni Graz
-
Pieske Burkert Mathias
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- Aims Cardiac resynchronization therapy (CRT) is sometimes complicated by elevated pacing thresholds and phrenic nerve stimulation (PNS), both of which may require that the coronary sinus lead be repositioned. The purpose of this study was to evaluate the performance of a novel quadripolar electrode lead and cardiac resynchronization therapy-defibrillator (CRT-D) device that enables electrical repositioning, potentially obviating a lead reposition procedure. Methods and results Patients indicated for CRT were enrolled and received a quadripolar electrode lead and CRT-D device (Quartetmodel 1458Q and Promote Q; St Jude Medical, Sylmar, CA, USA). Electrical data, and the presence of PNS during pacing from each left ventricular (LV) configuration, were documented at pre-hospital discharge and at 1 month. Seventy-five patients were enrolled and 71 were successfully implanted with a Quartetlead. Electrical measurements were stable over the follow-up period. Ninety-seven per cent (64 of 66) of patients had one or more programmable configurations with a threshold 2.5 V and no PNS vs. 86 (57 of 66) if only conventional bipolar configurations were considered. Physicians were able to use the increased programming options to manage threshold changes and PNS. Conclusion The new quadripolar electrode LV lead provides more programming options to address common problems faced when managing CRT patients. Electrical measurements from new vectors are comparable with conventional configurations. Furthermore, 11 of patients in the study suffered PNS on all conventional bipolar vectors.
- Find related publications in this database (using NLM MeSH Indexing)
-
Aged -
-
Cardiac Resynchronization Therapy Devices -
-
Electrodes, Implanted -
-
Female -
-
Heart Failure - therapy
-
Humans -
-
Male -
-
Middle Aged -
-
Myocardial Ischemia - therapy
-
Phrenic Nerve - physiopathology
-
Treatment Outcome -
-
Ventricular Dysfunction, Left - physiopathology Ventricular Dysfunction, Left - therapy
- Find related publications in this database (Keywords)
-
Cardiac resynchronization therapy
-
Quadripolar lead
-
Left ventricular pacing
-
Phrenic nerve stimulation
-
LV lead complications