Medizinische Universität Graz - Research portal

Logo MUG Resarch Portal

Selected Publication:

SHR Neuro Cancer Cardio Lipid Metab Microb

Giannini, C; Capodanno, D; Toth, GG; Windecker, S; Schüpke, S; Blackman, DJ; Noble, S; Eltchaninoff, H; Fiorina, C; Chieffo, A; Bartorelli, AL; Schmidt, A; De, Backer, O; Gilard, M; Curtis, E; L'Official, G; Donal, E; Laroche, C; Prendergast, B; Petronio, AS; The, European, Valve, Durability, Tavi, Registry, Investigators, OB.
Long-term structural valve deterioration after TAVI: insights from the EORP ESC Valve Durability TAVI Registry.
EuroIntervention. 2025; 21(10):537-549 Doi: 10.4244/EIJ-D-24-00662 [OPEN ACCESS]
PubMed PUBMED Central FullText FullText_MUG

 

Co-authors Med Uni Graz
Schmidt Albrecht
Toth-Gayor Gabor
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
BACKGROUND: Valve durability is a key consideration as the patient population eligible for transcatheter aortic valve implantation (TAVI) expands to include lower-risk and younger individuals who are expected to live many years after the procedure. AIMS: This registry aimed to assess the incidence of long-term structural valve deterioration (SVD) beyond 5 years post-TAVI. METHODS: Consecutive living patients who underwent TAVI up until 2014 using any commercially available transcatheter heart valve (THV) at 22 participant centres were enrolled in the European Valve Durability TAVI Registry. All patients underwent comprehensive echocardiographic assessments (61% were evaluated independently by a central core laboratory) within 6 months of enrolment and at least 5 years post-TAVI; SVD was defined according to Valve Academic Research Consortium 3 definitions. RESULTS: A total of 597 patients (aged 79.6±7.1 years at the time of TAVI; 47.2% male, mean Society of Thoracic Surgeons score 5.0%) were included. At a median of 6.1 years of follow-up (interquartile range 5.2-7.3 years), the crude incidence of moderate/severe SVD was 9.5% (n=57; moderate: 6.2%, n=37; severe: 3.4%, n=20). Predictors of SVD identified by Cox regression analysis were use of an intra-annular THV (hazard ratio [HR] 38.44, 95% confidence interval [CI]: 10.8-136.3; p<0.001), a small THV size (HR 4.82, 95% CI: 2.42-9.60; p<0.001) and moderate/severe postprocedural paravalvular leak (HR 3.64, 95% CI: 1.59-8.32; p=0.002). CONCLUSIONS: The incidence of moderate/severe SVD during long-term follow-up after TAVI is low, with severe SVD being even rarer than moderate SVD. SVD occurs more frequently in patients treated with older-generation intra-annular valves and in those with small-sized THVs.
Find related publications in this database (using NLM MeSH Indexing)
Humans - administration & dosage
Male - administration & dosage
Female - administration & dosage
Transcatheter Aortic Valve Replacement - adverse effects, methods
Aged - administration & dosage
Registries - administration & dosage
Aged, 80 and over - administration & dosage
Aortic Valve Stenosis - surgery
Aortic Valve - surgery, diagnostic imaging
Heart Valve Prosthesis - administration & dosage
Treatment Outcome - administration & dosage
Prosthesis Failure - administration & dosage
Risk Factors - administration & dosage
Time Factors - administration & dosage
Incidence - administration & dosage
Echocardiography - administration & dosage

© Med Uni GrazImprint