Medizinische Universität Graz - Research portal

Logo MUG Resarch Portal

Selected Publication:

SHR Neuro Cancer Cardio Lipid Metab Microb

Brodmann, M; Nemes, B; Moreels, N; Austermann, M; Schmehl, J; Robijn, J; Rammos, C; Müller-Hülsbeck, S; Keirse, K; Coscas, R; Kupcs, K; Augustin, AM; Moebius-Winkler, S; Lichtenberg, M; Lansink, W.
Dynetic-35 cobalt chromium balloon-expandable stent for iliac lesions: 12-month results of the BIONETIC-I multi-center study
CVIR ENDOVASC. 2025; 8(1): 114 Doi: 10.1186/s42155-025-00633-z [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Leading authors Med Uni Graz
Brodmann Marianne
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Purpose The BIONETIC-I trial aimed to evaluate the safety and effectiveness of the cobalt chromium Dynetic-35 stent, used in conjunction with the Passeo-35 Xeo peripheral dilation catheter, for treating atherosclerotic lesions in iliac arteries of patients with peripheral artery disease (PAD). Materials and methods This international, multi-center, prospective, single-arm study enrolled 160 subjects with 212 lesions across six European countries. The primary endpoint was a composite of major adverse events (MAE) at 12 months, including device- or procedure-related death within 30 days, clinically driven target lesion revasculari- zation (cdTLR), and major index limb amputation. Secondary endpoints included technical and procedural success, cdTLR rate, mortality, major amputation rate, primary patency, and changes in PAD-related parameters. Results The patients (61.9% male, median age 65 years) presented with predominantly calcified lesions (90.1%) and high-grade stenosis (average 85.5%), with 12.5% having CLTI.The 12-month MAE rate was 3.5% (97.5% upper con- fidence limit: 7.2%), significantly non-inferior to the pre-specified performance goal (p < 0.0001). Secondary endpoints showed favorable 12-month outcomes, including a low cdTLR rate (2.0%), robust core lab-reported primary patency (93.1%), and significant improvements in PAD-related parameters such as Ankle-Brachial Index, Rutherford classifica- tion, and Walking Impairment Questionnaire. Subgroup analysis revealed no differences in MAEs between patients with severe/moderate and mild/no calcification, with notable improvements in functional measures for those with severe/moderate calcification. Conclusion The balloon-expandable cobalt chromium stent Dynetic-35 demonstrated safety and effectiveness in treating iliac arteries at the 12-month timepoint, showing promising results across various patient subgroups, including those with calcified lesions.

Find related publications in this database (Keywords)
Peripheral artery disease (PAD)
Iliac artery stenting
Cobalt chromium stent
Endovascular treatment
Atherosclerotic lesions
© Med Uni GrazImprint