Selected Publication:
SHR
Neuro
Cancer
Cardio
Lipid
Metab
Microb
Eichlseder, M; Labenbacher, S; Schreiber, N; Kouz, K; Pichler, A; Eichinger, M; Müller, M; Zajic, P; Fandler-Höfler, S; Bornemann-Cimenti, H; Saugel, B.
Intraarterial blood pressure monitoring in prehospital emergency care: a scoping review.
Scand J Trauma Resusc Emerg Med. 2025; 33(1): 166
Doi: 10.1186/s13049-025-01473-5
[OPEN ACCESS]
PubMed
FullText
FullText_MUG
- Leading authors Med Uni Graz
-
Eichlseder Michael
-
Labenbacher Sebastian
- Co-authors Med Uni Graz
-
Bornemann-Cimenti Helmar
-
Eichinger Michael
-
Fandler-Höfler Simon
-
Pichler Alexander
-
Schreiber Nikolaus
-
Zajic Paul
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Scite (citation analytics):
- Abstract:
- BACKGROUND: Blood pressure is a key vital sign in prehospital emergency care and essential for assessing the hemodynamic status and guiding treatment. In the prehospital setting, blood pressure is usually measured intermittently with non-invasive cuff-techniques. However, intraarterial blood pressure monitoring with an arterial catheter offers continuous and more accurate measurements. This scoping review aimed to synthesize and analyze the current literature on intraarterial blood pressure monitoring in prehospital emergency care. METHODS: PubMed, EMBASE, MEDLINE, Cochrane Central, and CINAHL were searched on April 15, 2025, following PRISMA-ScR guidelines and Joanna Briggs Institute methodology. Studies involving adults (≥ 18 years) having prehospital intraarterial blood pressure monitoring were included. RESULTS: 1456 studies were screened and 24 studies finally included. The most frequent indications for intraarterial blood pressure monitoring were cardiopulmonary resuscitation and post resuscitation care. Arterial cannulation was performed by physicians in 92% of the cases. The radial artery was the most frequently used cannulation site. Arterial cannulation was successful in 82% of the patients. Major complications were very rare, with brachial artery cannulation bearing the highest risk for complications. Low agreement between intraarterial and non-invasive blood pressure measurements was reported. Actions based on intraarterial blood pressure monitoring were performed in 53% of the patients. Arterial cannulation was performed during different timepoints and had varying effects on prehospital time. CONCLUSIONS: Intraarterial blood pressure monitoring has been studied across a wide range of indications in prehospital emergency care with an acceptable cannulation success rate and low risk of complications. However, the included studies were mostly observational, necessitating randomized controlled trials analyzing patient-centered outcomes in defined populations.
- Find related publications in this database (using NLM MeSH Indexing)
-
Humans - administration & dosage
-
Emergency Medical Services - methods
-
Blood Pressure Determination - methods
-
Blood Pressure - physiology