Selected Publication:
Wasler, A; Petutschnigg, B; Iberer, F; Auer, T; Tscheliessnigg, KH.
[Noninvasive monitoring of rejection in heart transplant patients. An overview of current status and use at a small transplant center].
Wien Klin Wochenschr. 1991; 103(4):105-110
Web of Science
PubMed
- Leading authors Med Uni Graz
-
Wasler Andrae
- Co-authors Med Uni Graz
-
Auer-Schönbach Thomas
-
Iberer Florian
-
Petutschnigg Berthold
-
Tscheliessnigg Karlheinz
- Altmetrics:
- Dimensions Citations:
- Plum Analytics:
- Abstract:
-
In view of the numerous techniques known for noninvasive rejection monitoring for heart transplant recipients, it is important, especially for small transplant centres, to select suitable parameters for routine monitoring. We verified the methods for rejection monitoring and on the basis of the good results after orthotopic heart transplantation in our unit (33 patients, 78% overall survival, no death later than 6 months after transplantation), consider the following parameters useful for small transplant centres: heart/thorax ratio, echocardiography and neopterin. The Fast-Fourier analysis should prove of great value for small transplant units, given the availability of suitable apparatuses.
- Find related publications in this database (using NLM MeSH Indexing)
-
Biopsy -
-
Biopterin - analogs & derivatives
-
Biopterin - urine
-
Echocardiography - instrumentation
-
Electrocardiography - instrumentation
-
Endocardium - pathology
-
Graft Rejection - physiology
-
Heart Transplantation - physiology
-
Humans -
-
Lymphocyte Activation - immunology
-
Myocardium - pathology
-
Neopterin -
-
Postoperative Complications - diagnosis
-
Postoperative Complications - physiopathology
-
Signal Processing, Computer-Assisted - instrumentation
-
T-Lymphocytes - immunology
- Find related publications in this database (Keywords)
-
Heart Transplantation
-
Noninvasive Rejection Monitoring
-
Current Status