Medizinische Universität Graz - Research portal

Logo MUG Resarch Portal

Publications

Search Items: OSTEOSYNTHESIS, . hits: 77

2020

Dauwe, J; Walters, G; Holzer, LA; Vanhaecht, K; Nijs, S Failure after proximal humeral fracture osteosynthesis: a one year analysis of hospital-related healthcare cost.
Int Orthop. 2020; [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Hohenberger, GM; Schwarz, AM; Dauwe, J; Grechenig, P; Staresinic, M; Feigl, G; Bakota, B Evaluation of screw placement in proximal humerus fractures regarding drilling manoeuvre and surgeon's experience.
Injury. 2020;
PubMed FullText FullText_MUG

 

Hohenberger, GM; Schwarz, AM; Grechenig, P; Clement, B; Staresinic, M; Bakota, B Medial minimally invasive helical plate osteosynthesis of the distal femur - a new technique.
Injury. 2020; 19:
PubMed FullText FullText_MUG

 

Holweg, P; Berger, L; Cihova, M; Donohue, N; Clement, B; Schwarze, U; Sommer, NG; Hohenberger, G; van den Beucken, JJJP; Seibert, F; Leithner, A; Löffler, JF; Weinberg, AM A lean magnesium-zinc-calcium alloy ZX00 used for bone fracture stabilization in a large growing-animal model.
Acta Biomater. 2020; 113(2):646-659
Web of Science PubMed FullText FullText_MUG

 

Urbanschitz, L; Dreu, M; Wagner, J; Kaufmann, R; Jeserschek, JM; Borbas, P Cartilage and extensor tendon defects after headless compression screw fixation of phalangeal and metacarpal fractures
J HAND SURG-EUR VOL. 2020; 1753193420919060
Web of Science PubMed FullText FullText_MUG

 

2019

Neubauer, T; Grechenig, S; Clement, H; Leitner, L; Plecko, M; Auffarth, A Risk of extrapelvine vascular injuries in osteosynthesis with gliding hip screws.
Arch Orthop Trauma Surg. 2019; 139(3): 339-345.
Web of Science PubMed FullText FullText_MUG

 

Neubauer, T; Plecko, M; Grechenig, S; Hartmann, A; Ortmaier, R; Hitzl, W; Feigl, G Minimal invasive plating of distal radius fractures. A safe procedure?
Ann Anat. 2019; 224(6):172-178
Web of Science PubMed FullText FullText_MUG

 

2018

Grün, NG; Holweg, PL; Donohue, N; Klestil, T; Weinberg, AM Resorbable implants in pediatric fracture treatment.
Innov Surg Sci. 2018; 3(2):119-125 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Kraus, T; Fischerauer, S; Treichler, S; Martinelli, E; Eichler, J; Myrissa, A; Zötsch, S; Uggowitzer, PJ; Löffler, JF; Weinberg, AM The influence of biodegradable magnesium implants on the growth plate.
Acta Biomater. 2018; 66:109-117
Web of Science PubMed FullText FullText_MUG

 

Theopold, J; Schleifenbaum, S; Müller, M; Werner, M; Hammer, N; Josten, C; Hepp, P Biomechanical evaluation of hybrid double plate osteosynthesis using a locking plate and an inverted third tubular plate for the treatment of proximal humeral fractures.
PLoS One. 2018; 13(10):e0206349-e0206349 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

2017

Egger, J; Wallner, J; Gall, M; Chen, X; Schwenzer-Zimmerer, K; Reinbacher, K; Schmalstieg, D Computer-aided position planning of miniplates to treat facial bone defects.
PLoS One. 2017; 12(8):e0182839-e0182839 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Grechenig, S; Hohenberger, G; Bakota, B; Staresinic, M; Grechenig, P; Ernstberger, A Humeral shaft cerclage wiring: a safe technique to prevent radial nerve injury.
Injury. 2017; 48 Suppl 5(5):S12-S14
Web of Science PubMed FullText FullText_MUG

 

Holweg, P; Hohenberger, GM; Schwarz, AM; Staresinic, M; Krassnig, R; Grechenig, S Comparison of volar and dorsal plate osteosynthesis for radial shaft fractures: an anatomical pilot study.
Injury. 2017; 48 Suppl 5(5):S38-S40
Web of Science PubMed FullText FullText_MUG

 

Wallner, J; Reinbacher, K; Feichtinger, M; Pau, M; Feigl, G; Quehenberger, F; Schwenzer-Zimmerer, K; Zemann, W Osteosynthesis using cannulated headless Herbert screws in mandibular angle fracture treatment: A new approach?
J Craniomaxillofac Surg. 2017; 45(4):526-539
Web of Science PubMed FullText FullText_MUG

 

2016

Berger, L; Eichler, J; Ryll, EJS; Fischerauer, S; Raschke, MJ; Kolbitsch, A; Castellani, C; Weinberg, AM Advanced interlocking systems to improve heavy-load-bearing characteristics of flexible intramedullary nailing.
Mater Sci Eng C Mater Biol Appl. 2016; 68(8):358-365
Web of Science PubMed FullText FullText_MUG

 

Borbas, P; Dreu, M; Poggetti, A; Calcagni, M; Giesen, T Treatment of proximal phalangeal fractures with an antegrade intramedullary screw: a cadaver study.
J Hand Surg Eur Vol. 2016; 41(7):683-687
Web of Science PubMed FullText FullText_MUG

 

Gänsslen, A; Grechenig, ST; Nerlich, M; Müller, M; Grechenig, W Standard Approaches to the Acetabulum Part 2: Ilioinguinal Approach.
Acta Chir Orthop Traumatol Cech. 2016; 83(4):217-222
Web of Science PubMed

 

Maier, M; Bratschitsch, G; Friesenbichler, J; Bodo, K; Leithner, A; Holzer, LA Pathologic fracture of the distal humerus due to a textiloma.
J Shoulder Elbow Surg. 2016; 25(10):e304-e308
Web of Science PubMed FullText FullText_MUG

 

Neubauer, T; Grechenig, S; Leitner, L; Auffarth, A; Plecko, M Vascular complications in plating of the proximal femur: review.
Arch Orthop Trauma Surg. 2016; 136(4):539-551 [OPEN ACCESS]
Web of Science PubMed FullText FullText_MUG

 

2015

Grechenig, S; Dreu, M; Clement, H; Plecko, M; Pichler, W; Gänsslen, A; Krutsch, W Minimal Invasive Dorsal Plate Osteosynthesis of the Tibia--Are Nerves and Vessels at Risk? An Anatomical Study.
Acta Chir Orthop Traumatol Cech. 2015; 82(5):337-340
Web of Science PubMed

 

Matzi, V; Hörlesberger, N; Hohenberger, GM; Rosenlechner, D; Dolcet, C; Weiglein, AH; Maier, MJ; Grechenig, S Minimally invasive approach to the radial nerve--A new technique.
Injury. 2015; 46(12):2374-2378
Web of Science PubMed FullText FullText_MUG

 

Zajonz, D; Pfraenger, JR; Dubitzki, S; Panzert, S; Seider, D; Lingscheidt, T; Hammer, N; Prietzel, T [Subtotal Segment Resection, Augmenting Angle-Stable Plate Osteosynthesis and Allogenic Bone Graft as Treatment Option for Juxtacortical Osteosarcoma in the Knee Region].
Z Orthop Unfall. 2015; 153(3):299-305 (- Case Report)
Web of Science PubMed FullText FullText_MUG

 

2014

Ferlic, PW; Sadoghi, P; Singer, G; Kraus, T; Eberl, R Treatment for ischial tuberosity avulsion fractures in adolescent athletes.
Knee Surg Sports Traumatol Arthrosc. 2014; 22(4):893-897
Web of Science PubMed FullText FullText_MUG

 

Kraus, T; Moszner, F; Fischerauer, S; Fiedler, M; Martinelli, E; Eichler, J; Witte, F; Willbold, E; Schinhammer, M; Meischel, M; Uggowitzer, PJ; Löffler, JF; Weinberg, A Biodegradable Fe-based alloys for use in osteosynthesis: outcome of an in vivo study after 52 weeks.
Acta Biomater. 2014; 10(7):3346-3353
Web of Science PubMed FullText FullText_MUG

 

2013

Kohn, L; Sauerschnig, M; Iskansar, S; Lorenz, S; Meidinger, G; Imhoff, AB; Hinterwimmer, S Age does not influence the clinical outcome after high tibial osteotomy.
Knee Surg Sports Traumatol Arthrosc. 2013; 21(1): 146-151.
Web of Science PubMed FullText FullText_MUG

 

Puchwein, P; Jester, B; Freytag, B; Tanzer, K; Maizen, C; Gumpert, R; Pichler, W The three-dimensional morphometry of the odontoid peg and its impact on ventral screw osteosynthesis.
Bone Joint J. 2013; 95-B(4):536-542
Web of Science PubMed FullText FullText_MUG

 

2012

Celarek, A; Kraus, T; Tschegg, EK; Fischerauer, SF; Stanzl-Tschegg, S; Uggowitzer, PJ; Weinberg, AM PHB, crystalline and amorphous magnesium alloys: promising candidates for bioresorbable osteosynthesis implants?
Mater Sci Eng C Mater Biol Appl. 2012; 32(6):1503-1510
Web of Science PubMed FullText FullText_MUG

 

Gänsslen, A; Hildebrand, F; Heidari, N; Weinberg, AM Pelvic ring injuries in children. Part I: Epidemiology and primary evaluation. A review of the literature.
ACTA CHIR ORTHOP TRAUMATOL CE. 2012; 79(6): 493-498.
Web of Science PubMed

 

Rothstock, S; Plecko, M; Kloub, M; Schiuma, D; Windolf, M; Gueorguiev, B Biomechanical evaluation of two intramedullary nailing techniques with different locking options in a three-part fracture proximal humerus model.
Clin Biomech (Bristol, Avon). 2012; 27(7): 686-691.
Web of Science PubMed FullText FullText_MUG

 

2011

Böhme, J; Steinke, H; Huelse, R; Hammer, N; Klink, T; Slowik, V; Josten, C [Complex ligament instabilities after "open book"-fractures of the pelvic ring - finite element computer simulation and crack simulation].
Z Orthop Unfall. 2011; 149(1):83-89
Web of Science PubMed FullText FullText_MUG

 

Grechenig, W; Heidari, N; Leitgoeb, O; Prager, W; Pichler, W; Weinberg, AM Is plating of mid-shaft clavicular fractures possible with a conventional straight 3.5 millimeter locking compression plate?
Acta Orthop Traumatol Turc. 2011; 45(2): 115-119. [OPEN ACCESS]
Web of Science PubMed FullText FullText_MUG

 

Heidari, N; Eberl, R; Wiklicky, S; Evers, K; Weinberg, AM Anatomical landmarks in the paediatric distal radius: a new method for measuring epiphyseal height.
Surg Radiol Anat. 2011; 33(8): 683-687.
Web of Science PubMed FullText FullText_MUG

 

Kraus, R; Röder, C; Perler, G; Schneidmüller, D; Sommerfeldt, D; Wessel, L; Schnettler, R; Linhart, W [Do paediatric and adult surgeons follow different approaches to physeal fractures?].
Zentralbl Chir. 2011; 136(2):164-167
Web of Science PubMed FullText FullText_MUG

 

Neubauer, T; Heidari, N; Weinberg, AM; Grechenig, W; Tesch, NP; Pichler, W; Wagner, M The risk of nerve injury with minimally invasive plate osteosynthesis of distal fibula fractures: an anatomic study.
Arch Orthop Trauma Surg. 2011; 131(10): 1409-1412.
Web of Science PubMed FullText FullText_MUG

 

Puchwein, P; Wildburger, R; Archan, S; Guschl, M; Tanzer, K; Gumpert, R Outcome of type C (AO) distal humeral fractures: follow-up of 22 patients with bicolumnar plating osteosynthesis.
J Shoulder Elbow Surg. 2011; 20(4): 631-636.
Web of Science PubMed FullText FullText_MUG

 

Seemann, R; Lauer, G; Poeschl, PW; Schicho, K; Pirklbauer, M; Russmüller, G; Krennmair, G; Perisanidis, C; Ewers, R; Klug, C CROOMA, complication rates of operatively treated mandibular fractures, paramedian and body.
Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2011; 111(4): 449-454.
Web of Science PubMed FullText FullText_MUG

 

Seemann, R; Undt, G; Lauer, G; Holawe, S; Schicho, K; Czerny, C; Krennmair, G; Ewers, R; Klug, C; Perisanidis, C Is failure of condylar neck osteosynthesis predictable based on orthopantomography?
Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2011; 111(3): 362-371.
Web of Science PubMed FullText FullText_MUG

 

2010

Seemann, R; Perisanidis, C; Schicho, K; Wutzl, A; Poeschl, WP; Köhnke, R; Kinast, B; Brunner, J; Krennmair, G; Ewers, R; Klug, C Complication rates of operatively treated mandibular fractures--the mandibular neck.
Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010; 109(6): 815-819.
Web of Science PubMed FullText FullText_MUG

 

Seemann, R; Schicho, K; Wutzl, A; Koinig, G; Poeschl, WP; Krennmair, G; Ewers, R; Klug, C Complication rates in the operative treatment of mandibular angle fractures: a 10-year retrospective.
J Oral Maxillofac Surg. 2010; 68(3): 647-650.
Web of Science PubMed FullText FullText_MUG

 

2009

Pichler, W; Grechenig, W; Tesch, NP; Weinberg, AM; Heidari, N; Clement, H The risk of iatrogenic injury to the deep peroneal nerve in minimally invasive osteosynthesis of the tibia with the less invasive stabilisation system: a cadaver study.
J Bone Joint Surg Br. 2009; 91(3): 385-387. [OPEN ACCESS]
Web of Science PubMed FullText FullText_MUG

 

Reichwein, A; Schicho, K; Moser, D; Seemann, R; Poeschl, P; Baumann, A; Ewers, R Clinical experiences with resorbable ultrasonic-guided, angle-stable osteosynthesis in the panfacial region.
J Oral Maxillofac Surg. 2009; 67(6): 1211-1217.
Web of Science PubMed FullText FullText_MUG

 

Schalamon, J; Petnehazy, T The management of traumatic fractures in children.
Minerva Pediatr. 2009; 61(2):185-192
PubMed

 

2008

Nork, SE; Barei, DP; Gardner, MJ; Schildhauer, TA; Mayo, KA; Benirschke, SK Surgical exposure and fixation of displaced type IV, V, and VI glenoid fractures.
J Orthop Trauma. 2008; 22(7):487-493
Web of Science PubMed FullText FullText_MUG

 

Pichler, W; Clement, H; Hausleitner, L; Tanzer, K; Tesch, NP; Grechenig, W Various circular arc radii of the distal volar radius and the implications on volar plate osteosynthesis.
Orthopedics. 2008; 31(12): 1192-1192.
Web of Science PubMed

 

2007

Seemann, R; Schicho, K; Reichwein, A; Eisenmenger, G; Ewers, R; Wagner, A Clinical evaluation of mechanically optimized plates for the treatment of condylar process fractures.
Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007; 104(6): e1-e4.
Web of Science PubMed FullText FullText_MUG

 

Weinberg, AM; Castellani, C; Arzdorf, M; Schneider, E; Gasser, B; Linke, B Osteosynthesis of supracondylar humerus fractures in children: a biomechanical comparison of four techniques.
Clin Biomech (Bristol, Avon). 2007; 22(5): 502-509.
Web of Science PubMed FullText FullText_MUG

 

Windisch, G; Clement, H; Grechenig, W; Tesch, NP; Pichler, W A morphometrical study of the medullary cavity of the ulna referred to intramedullary nailing.
Surg Radiol Anat. 2007; 29(1): 47-53.
Web of Science PubMed FullText FullText_MUG

 

2006

Klug, C; Schicho, K; Ploder, O; Yerit, K; Watzinger, F; Ewers, R; Baumann, A; Wagner, A Point-to-point computer-assisted navigation for precise transfer of planned zygoma osteotomies from the stereolithographic model into reality.
J Oral Maxillofac Surg. 2006; 64(3): 550-559.
Web of Science PubMed FullText FullText_MUG

 

Roetman, B; Schildhauer, TA; Muhr, G Pelvic stabilization in cases of septic instability. Triangular osteosynthesis in case of infection related vertical pelvic ring instability
Unfallchirurg. 2006; 109(5):422-424 (- Case Report)
Web of Science PubMed FullText FullText_MUG

 

Schildhauer, TA; Josten, Ch; Muhr, G Triangular osteosynthesis of vertically unstable sacrum fractures: a new concept allowing early weight-bearing.
J Orthop Trauma. 2006; 20(1 Suppl):S44-S51
PubMed

 

Show the next 50 results of search
© Med Uni GrazImprint