Search Items: BONE SCREWS - , . hits: 58
Freimoser, F; Grechenig, S; Ofenhitzer, A; Bakota, B; Staresinic, M; Pfeifer, CG
Anatomical and radiological evaluation of less invasive stabilisation system (LISS) in correlation with knee lateral collateral ligament insertion.
Injury. 2017; 48 Suppl 5(1):S56-S60
Doi: 10.1016/S0020-1383(17)30741-6
Web of Science
PubMed
FullText
FullText_MUG
Höch, A; Schimpf, R; Hammer, N; Schleifenbaum, S; Werner, M; Josten, C; Böhme, J
Biomechanical analysis of stiffness and fracture displacement after using PMMA-augmented sacroiliac screw fixation for sacrum fractures.
Biomed Tech (Berl). 2017; 62(4):421-428
Doi: 10.1515/bmt-2016-0235
Web of Science
PubMed
FullText
FullText_MUG
Hohenberger, GM; Berzins, U; Bakota, B; Holweg, P; Clement, B; Grechenig, S
Scaphoid screw placement under minimal radiation exposure.
Injury. 2017; 48 Suppl 5(1):S47-S50
Doi: 10.1016/S0020-1383(17)30739-8
Web of Science
PubMed
FullText
FullText_MUG
Krassnig, R; Orlandi, JA; Tackner, E; Hohenberger, G; Puchwein, P
Computer-aided analysis for optimal screw insertion in lateral mass of C1: An anatomical study.
Arch Orthop Trauma Surg. 2017; 137(6):817-822
Doi: 10.1007/s00402-017-2678-y
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
Osterhoff, G; Aichner, EV; Scherer, J; Simmen, HP; Werner, CML; Feigl, GC
Anterior subcutaneous internal fixation of the pelvis - what rod-to-bone distance is anatomically optimal?
Injury. 2017; 48(10):2162-2168
Doi: 10.1016/j.injury.2017.08.047
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
Vidović, D; Elabjer, E; Muškardin, IVA; Milosevic, M; Bekic, M; Bakota, B
Posterior fragment in ankle fractures: anteroposterior vs posteroanterior fixation.
Injury. 2017; 48 Suppl 5(1):S65-S69
Doi: 10.1016/S0020-1383(17)30743-X
Web of Science
PubMed
FullText
FullText_MUG
Wallner, J; Reinbacher, K; Feichtinger, M; Pau, M; Feigl, G; Quehenberger, F; Schwenzer-Zimmerer, K; Zemann, W
Osteosynthesis using cannulated headless Herbert screws in mandibular angle fracture treatment: A new approach?
J Craniomaxillofac Surg. 2017; 45(4):526-539
Doi: 10.1016/j.jcms.2017.01.025
Web of Science
PubMed
FullText
FullText_MUG
Arnetzl, GV; Payer, M; Falkensammer, F; Arnetzl, G
Effect of double conical abutment screw on implant preload.
Clin Oral Implants Res. 2016; 27(5):553-557
Doi: 10.1111/clr.12623
Web of Science
PubMed
FullText
FullText_MUG
Berger, L; Eichler, J; Ryll, EJS; Fischerauer, S; Raschke, MJ; Kolbitsch, A; Castellani, C; Weinberg, AM
Advanced interlocking systems to improve heavy-load-bearing characteristics of flexible intramedullary nailing.
Mater Sci Eng C Mater Biol Appl. 2016; 68(8):358-365
Doi: 10.1016/j.msec.2016.05.122
Web of Science
PubMed
FullText
FullText_MUG
Borbas, P; Dreu, M; Poggetti, A; Calcagni, M; Giesen, T
Treatment of proximal phalangeal fractures with an antegrade intramedullary screw: a cadaver study.
J Hand Surg Eur Vol. 2016; 41(7):683-687
Doi: 10.1177/1753193416641319
Web of Science
PubMed
FullText
FullText_MUG
Chen, X; Xu, L; Yang, Y; Egger, J
A semi-automatic computer-aided method for surgical template design.
Sci Rep. 2016; 6(2): 20280-20280.
Doi: 10.1038/srep20280
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
Möbius, R; Schleifenbaum, S; Grunert, R; Löffler, S; Werner, M; Prietzel, T; Hammer, N
A pilot trial comparing the tear-out behavior in screw-sockets and cemented polyethylene acetabular components - a cadaveric study.
Orthop Traumatol Surg Res. 2016; 102(6):723-728
Doi: 10.1016/j.otsr.2016.06.007
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
Bukva, B; Abramović, D; Vrgoč, G; Marinović, M; Bakota, B; Dučić, S; Miškulin, M; Brdar, R; Čoklo, M; Gulan, G
Femoral neck fractures in children and the role of early hip decompression in final outcome.
Injury. 2015; 46 Suppl 6:S44-S47
Doi: 10.1016/j.injury.2015.10.059
Web of Science
PubMed
FullText
FullText_MUG
Kaftandziev, I; Spasov, M; Trpeski, S; Zafirova-Ivanovska, B; Bakota, B
Fate of the syndesmotic screw--Search for a prudent solution.
Injury. 2015; 46 Suppl 6:S125-S129
Doi: 10.1016/j.injury.2015.10.062
Web of Science
PubMed
FullText
FullText_MUG
Richter, H; Plecko, M; Andermatt, D; Frigg, R; Kronen, PW; Klein, K; Nuss, K; Ferguson, SJ; Stöckle, U; von Rechenberg, B
Dynamization at the near cortex in locking plate osteosynthesis by means of dynamic locking screws: an experimental study of transverse tibial osteotomies in sheep.
J Bone Joint Surg Am. 2015; 97(3): 208-215.
Doi: 10.2106/JBJS.M.00529
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
Muchitsch, AP; Winsauer, H; Wendl, B; Pichelmayer, M; Kuljuh, E; Navysany, MT; Muchitsch, M
Effects of a hinged expansion screw for median mandibular distraction treatment on the lower first molars regarding tooth inclination and intermolar transverse distance.
J Orofac Orthop. 2014; 75(1):25-35
Doi: 10.1007/s00056-013-0191-7
Web of Science
PubMed
FullText
FullText_MUG
Parker, L; Ray, P; Grechenig, S; Grechenig, W
Does the IOFIX improve compression in ankle fusion?
Foot Ankle Surg. 2014; 20(4): 258-261.
Doi: 10.1016/j.fas.2014.06.004
Web of Science
PubMed
FullText
FullText_MUG
Plecko, M; Lagerpusch, N; Andermatt, D; Frigg, R; Koch, R; Sidler, M; Kronen, P; Klein, K; Nuss, K; Bürki, A; Ferguson, SJ; Stoeckle, U; Auer, JA; von Rechenberg, B
The dynamisation of locking plate osteosynthesis by means of dynamic locking screws (DLS)-an experimental study in sheep.
Injury. 2013; 44(10): 1346-1357.
Doi: 10.1016/j.injury.2012.10.022
Web of Science
PubMed
FullText
FullText_MUG
Puchwein, P; Jester, B; Freytag, B; Tanzer, K; Maizen, C; Gumpert, R; Pichler, W
The three-dimensional morphometry of the odontoid peg and its impact on ventral screw osteosynthesis.
Bone Joint J. 2013; 95-B(4):536-542
Doi: 10.1302/0301-620X.95B4.30949
Web of Science
PubMed
FullText
FullText_MUG
Schiuma, D; Plecko, M; Kloub, M; Rothstock, S; Windolf, M; Gueorguiev, B
Influence of peri-implant bone quality on implant stability.
Med Eng Phys. 2013; 35(1): 82-87.
Doi: 10.1016/j.medengphy.2012.04.001
Web of Science
PubMed
FullText
FullText_MUG
Winsauer, H; Muchitsch, AP; Winsauer, C; Milnes, R; Vlachojannis, J; Walter, A
The TopJet for routine bodily molar distalization.
J Clin Orthod. 2013; 47(2):96-107
(- Case Report)
PubMed
Druschel, C; Sawicki, O; Cip, J; Schmölz, W; Funk, JF; Placzek, R
Biomechanical analysis of screw fixation vs. K-wire fixation of a slipped capital femoral epiphysis model.
Biomed Tech (Berl). 2012; 57(3): 157-162.
Doi: 10.1515/bmt-2011-0127
Web of Science
PubMed
FullText
FullText_MUG
Plecko, M; Lagerpusch, N; Pegel, B; Andermatt, D; Frigg, R; Koch, R; Sidler, M; Kronen, P; Klein, K; Nuss, K; Gedet, P; Bürki, A; Ferguson, SJ; Stoeckle, U; Auer, JA; von Rechenberg, B
The influence of different osteosynthesis configurations with locking compression plates (LCP) on stability and fracture healing after an oblique 45° angle osteotomy.
Injury. 2012; 43(7): 1041-1051.
Doi: 10.1016/j.injury.2011.12.016
Web of Science
PubMed
FullText
FullText_MUG
Puchwein, P; Enninghorst, N; Sisak, K; Ortner, T; Schildhauer, TA; Balogh, ZJ; Pichler, W
Percutaneous fixation of acetabular fractures: computer-assisted determination of safe zones, angles and lengths for screw insertion.
Arch Orthop Trauma Surg. 2012; 132(6):805-811
Doi: 10.1007/s00402-012-1486-7
Web of Science
PubMed
FullText
FullText_MUG
Benlidayi, ME; Gaggl, A; Bürger, H; Brandner, C; Kurkcu, M; Unlügenç, H
Comparative study of the osseointegration of dental implants after different bone augmentation techniques: vascularized femur flap, non-vascularized femur graft and mandibular bone graft.
Clin Oral Implants Res. 2011; 22(6):594-599
Doi: 10.1111/j.1600-0501.2010.02013.x
Web of Science
PubMed
FullText
FullText_MUG
Lübbers, HT; Matthews, F; Zemann, W; Grätz, KW; Obwegeser, JA; Bredell, M
Registration for computer-navigated surgery in edentulous patients: A problem-based decision concept.
J Craniomaxillofac Surg. 2011; 39(6):453-458
Doi: 10.1016/j.jcms.2010.10.021
[OPEN ACCESS]
Web of Science
PubMed
FullText
FullText_MUG
Singer, G; Eberl, R; Hoellwarth, ME
Pisotriquetral Arthrodesis for Pisotriquetral Instability: Case Report
J HAND SURG-AM. 2011; 36A(2): 299-303.
Doi: 10.1016/j.jhsa.2010.10.010
Web of Science
PubMed
FullText
FullText_MUG
Schadel-Hopfner, M; Marent-Huber, M; Gazyakan, E; Tanzer, K; Werber, KD; Siebert, HR
Acute non-displaced fractures of the scaphoid: earlier return to activities after operative treatment. A controlled multicenter cohort study.
Arch Orthop Trauma Surg. 2010; 130(9):1117-1127
Doi: 10.1007/s00402-009-1004-8
Web of Science
PubMed
FullText
FullText_MUG
Seemann, R; Perisanidis, C; Schicho, K; Wutzl, A; Poeschl, WP; Köhnke, R; Kinast, B; Brunner, J; Krennmair, G; Ewers, R; Klug, C
Complication rates of operatively treated mandibular fractures--the mandibular neck.
Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010; 109(6): 815-819.
Doi: 10.1016/j.tripleo.2009.11.033
Web of Science
PubMed
FullText
FullText_MUG
Castellani, C; Riedl, G; Eberl, R; Grechenig, S; Weinberg, AM
Transitional fractures of the distal tibia: a minimal access approach for osteosynthesis.
J Trauma. 2009; 67(6): 1371-1375.
Doi: 10.1097/TA.0b013e31818866fd
Web of Science
PubMed
FullText
FullText_MUG
Seemann, R; Frerich, B; Müller, S; Koenke, R; Ploder, O; Schicho, K; Piffko, J; Poeschl, P; Wagner, A; Wanschitz, F; Krennmair, G; Ewers, R; Klug, C
Comparison of locking and nonlocking plates in the treatment of mandibular condyle fractures.
Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009; 108(3): 328-334.
Doi: 10.1016/j.tripleo.2009.04.026
Web of Science
PubMed
FullText
FullText_MUG
Weinberg, AM; Pichler, W; Grechenig, S; Tesch, NP; Heidari, N; Grechenig, W
The percutaneous antegrade scaphoid fracture fixation--a safe method?
Injury. 2009; 40(6): 642-644.
Doi: 10.1016/j.injury.2008.12.016
Web of Science
PubMed
FullText
FullText_MUG
Feichtinger, M; Schultes, G; Karcher, H
The use of a 3D navigation system in the treatment of mandibular angle fractures by minimally invasive insertion of Herbert screws for osteosynthesis.
Comput Aided Surg. 2008; 13(1):47-54
Doi: 10.3109/10929080701882572
Web of Science
PubMed
FullText
FullText_MUG
Ivanic, GM; Pink, PT; Ziegler, S; Harter, B; Schneider, F; Plattner, F; Homann, NC
Mid-term outcome after fusion due to isthmic spondylolysis.
Wien Med Wochenschr. 2007; 157(1-2): 16-20.
Doi: 10.1007/s10354-006-0366-6
PubMed
FullText
FullText_MUG
Schicho, K; Figl, M; Seemann, R; Donat, M; Pretterklieber, ML; Birkfellner, W; Reichwein, A; Wanschitz, F; Kainberger, F; Bergmann, H; Wagner, A; Ewers, R
Comparison of laser surface scanning and fiducial marker-based registration in frameless stereotaxy. Technical note.
J Neurosurg. 2007; 106(4):704-709
Doi: 10.3171/jns.2007.106.4.704
Web of Science
PubMed
FullText
FullText_MUG
Schildhauer, TA; Bellabarba, C; Selznick, HS; McRoberts, D; Vedder, NB; Chapman, JR
Unstable pediatric sacral fracture with bone loss caused by a high-energy gunshot injury.
J Trauma. 2007; 63(4):E95-E99
Doi: 10.1097/01.ta.0000246879.13468.32
(- Case Report)
PubMed
FullText
FullText_MUG
Haxhija, EQ; Mayr, JM; Grechenig, W; Höllwarth, ME
Treatment of medial epicondylar apophyseal avulsion injury in children.
Oper Orthop Traumatol. 2006; 18(2): 120-134.
Doi: 10.1007/s00064-006-1166-2
PubMed
FullText
FullText_MUG
Roetman, B; Schildhauer, TA; Muhr, G
Pelvic stabilization in cases of septic instability. Triangular osteosynthesis in case of infection related vertical pelvic ring instability
Unfallchirurg. 2006; 109(5):422-424
Doi: 10.1007/s00113-006-1112-7
(- Case Report)
Web of Science
PubMed
FullText
FullText_MUG
Schildhauer, TA; Josten, Ch; Muhr, G
Triangular osteosynthesis of vertically unstable sacrum fractures: a new concept allowing early weight-bearing.
J Orthop Trauma. 2006; 20(1 Suppl):S44-S51
Doi: 10.1097/01.bot.0000202392.24999.7c
PubMed
FullText
FullText_MUG
Boldin, C; Grechenig, W; Fankhauser, F
Accident-induced late complaint of odontoid nonunion.
Spine. 2004; 29(8):E169-E171
Doi: 10.1097%2F00007632-200404150-00027
(- Case Report)
Web of Science
PubMed
FullText
FullText_MUG
Fankhauser, F; Passler, JM; Schippinger, G; Boldin, C; Scarpatetti, M
Tendon-to-bone healing of a quadrupled hamstring tendon graft fixed with biodegradable screws in an immature athlete: a radiologic, arthroscopic, histologic, and electromicroscopic investigation.
ARTHROSCOPY. 2004; 20(9): 992-997.
Doi: 10.1016/j.arthro.2004.08.007
(- Case Report)
Web of Science
PubMed
FullText
FullText_MUG
Saraph, V; Zwick, EB; Maizen, C; Schneider, F; Linhart, WE
Treatment of unicameral calcaneal bone cysts in children: review of literature and results using a cannulated screw for continuous decompression of the cyst.
J Pediatr Orthop. 2004; 24(5):568-573
Doi: 10.1097/01241398-200409000-00019
(- Case Report)
Web of Science
PubMed
FullText
FullText_MUG
Fankhauser, F; Schippinger, G; Weber, K; Heinz, S; Quehenberger, F; Boldin, C; Bratschitsch, G; Szyszkowitz, R; Georg, L; Friedrich, A
Cadaveric-biomechanical evaluation of bone-implant construct of proximal humerus fractures (Neer type 3).
J Trauma. 2003; 55(2):345-349
Doi: 10.1097/01.TA.0000033139.61038.EF
Web of Science
PubMed
FullText
FullText_MUG
Google Scholar
Schildhauer, TA; Ledoux, WR; Chapman, JR; Henley, MB; Tencer, AF; Routt, MLC
Triangular osteosynthesis and iliosacral screw fixation for unstable sacral fractures: a cadaveric and biomechanical evaluation under cyclic loads.
J Orthop Trauma. 2003; 17(1):22-31
Doi: 10.1097/00005131-200301000-00004
Web of Science
PubMed
FullText
FullText_MUG
Schultes, G; Zimmermann, V; Feichtinger, M; Gaggl, A; Kärcher, H
Removal of osteosynthesis material by minimally invasive surgery based on 3-dimensional computed tomography-guided navigation.
J Oral Maxillofac Surg. 2003; 61(3):401-405
Doi: 10.1053/joms.2003.50067
(- Case Report)
Web of Science
PubMed
FullText
FullText_MUG
Schildhauer, TA; McCulloch, P; Chapman, JR; Mann, FA; Gokaslan, ZL
Anatomic and radiographic considerations for placement of transiliac screws in lumbopelvic fixations.
J SPINAL DISORD TECH. 2002; 15(3): 199-205.
Doi: 10.1097/00024720-200206000-00005
Web of Science
PubMed
FullText
FullText_MUG
Schildhauer, TA; Sangeorzan, BJ
Push screw for indirect reduction of severe joint depression-type calcaneal fractures.
J ORTHOP TRAUMA. 2002; 16(6): 422-424.
Doi: 10.1097/00005131-200207000-00010
Web of Science
PubMed
FullText
FullText_MUG
Grechenig, W; Peicha, G; Clement, HG; Preidler, KW
Ultrasonographic localization of a displaced screw in the carpal canal. A case report.
Acta Radiol. 1999; 40(6):625-627
Doi: 10.3109/02841859909175599
(- Case Report)
Web of Science
PubMed
FullText
FullText_MUG
Seitz, H; Vecsei, V; Menth-Chiari, WA; Pichl, W; Wielke, B; Marlovits, S
Comparison of femoral and tibial pullout forces in bone-patellar tendon-bone anterior cruciate ligament reconstructions with a new interference fixation device
Arthroscopy. 1999; 15(2):173-178
Doi: 10.1053/ar.1999.v15.015017
Web of Science
PubMed
FullText
FullText_MUG
Fechter, M; Mayr, J; Linhart, WE
Pediatric scaphoid fractures--treatment and prognosis
Handchir Mikrochir Plast Chir. 1998; 30(4): 239-242.
PubMed
Show the next 50 results of search