Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Publikationen

Suchbegriffe: EQUIPMENT FAILURE ANALYSIS - , . Treffer: 33

2017

Grunert, R; Schleifenbaum, S; Möbius, R; Sommer, G; Zajonz, D; Hammer, N; Prietzel, T [Are Higher Prices for Larger Femoral Heads in Total Hip Arthroplasty Justified from the Perspective of Health Care Economics? An Analysis of Costs and Effects in Germany].
Z Orthop Unfall. 2017; 155(1):52-60
Web of Science PubMed FullText FullText_MUG

 

2016

Schwarzl, M; Alogna, A; Zweiker, D; Verderber, J; Huber, S; Manninger, M; Scherr, D; Antoons, G; Pieske, BM; Post, H; Lueger, A A porcine model of early atrial fibrillation using a custom-built, radio transmission-controlled pacemaker.
J Electrocardiol. 2016; 49(2):124-131
Web of Science PubMed FullText FullText_MUG

 

2015

Chen, X; Xu, L; Wang, Y; Wang, H; Wang, F; Zeng, X; Wang, Q; Egger, J Development of a surgical navigation system based on augmented reality using an optical see-through head-mounted display.
J Biomed Inform. 2015; 55(2):124-131 [OPEN ACCESS]
Web of Science PubMed FullText FullText_MUG

 

Clement, H; Zopf, C; Brandner, M; Tesch, NP; Vallant, R; Puchwein, P Performance test of different 3.5 mm drill bits and consequences for orthopaedic surgery.
Arch Orthop Trauma Surg. 2015; 135(12):1675-1682
Web of Science PubMed FullText FullText_MUG

 

Zajonz, D; Philipp, H; Schleifenbaum, S; Möbius, R; Hammer, N; Grunert, R; Prietzel, T [Larger heads compensate for an increased risk of THA dislocation in high-risk patients].
Orthopade. 2015; 44(5):381-391
Web of Science PubMed FullText FullText_MUG

 

2014

Matzke, C; Hammer, N; Weise, D; Lindner, D; Fritzsch, D; Classen, J; Meixensberger, J; Winkler, D [Deep brain stimulation using simultaneous stereotactic electrode placement: an alternative to conventional functional stereotaxy?].
Nervenarzt. 2014; 85(12):1561-1568
Web of Science PubMed FullText FullText_MUG

 

2013

Hirsch, FW; Sattler, B; Sorge, I; Kurch, L; Viehweger, A; Ritter, L; Werner, P; Jochimsen, T; Barthel, H; Bierbach, U; Till, H; Sabri, O; Kluge, R PET/MR in children. Initial clinical experience in paediatric oncology using an integrated PET/MR scanner.
Pediatr Radiol. 2013; 43(7):860-875 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Kamlin, CO; Schilleman, K; Dawson, JA; Lopriore, E; Donath, SM; Schmölzer, GM; Walther, FJ; Davis, PG; Te Pas, AB Mask versus nasal tube for stabilization of preterm infants at birth: a randomized controlled trial.
Pediatrics. 2013; 132(2):e381-e388 [OPEN ACCESS]
Web of Science PubMed FullText FullText_MUG

 

Vavken, P; Sadoghi, P; von Keudell, A; Rosso, C; Valderrabano, V; Müller, AM Rates of radiolucency and loosening after total shoulder arthroplasty with pegged or keeled glenoid components.
J Bone Joint Surg Am. 2013; 95(3):215-221
Web of Science PubMed FullText FullText_MUG

 

2012

Druschel, C; Sawicki, O; Cip, J; Schmölz, W; Funk, JF; Placzek, R Biomechanical analysis of screw fixation vs. K-wire fixation of a slipped capital femoral epiphysis model.
Biomed Tech (Berl). 2012; 57(3): 157-162.
Web of Science PubMed FullText FullText_MUG

 

Faschinger, C; Mossböck, G; Krainz, S Validity and reproducibility of sensor contact lens profiles in comparison to applanation tonometry in healthy eyes].
Klin Monbl Augenheilkd. 2012; 229(12):1209-1214
Web of Science PubMed FullText FullText_MUG

 

Friesenbichler, J; Glehr, M; Sadoghi, P; Maurer-Ertl, W; Ott, F; Leithner, A In vivo testing of knee stability after rotating-hinge total knee arthroplasty: a comparison of 2 knee systems.
Orthopedics. 2012; 35(3):e335-e342
Web of Science PubMed FullText FullText_MUG

 

Friesenbichler, J; Schwarzkopf, R; Sadoghi, P; Marwin, SE; Glehr, M; Maurer-Ertl, W; Leithner, A Failure rate of a rotating hinge knee design due to yoke fracture of the hinged tibial insert: a retrospective data analysis and review of the literature.
Int Orthop. 2012; 36(5):993-998 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Frings, A; Steinbrugger, I; Wissiak, E; Vidic, B; El-Shabrawi, Y; Ardjomand, N Refractive predictability and stability of three-piece versus single-piece intraocular lenses in patients with high axial myopia.
Ophthalmologe. 2012; 109(6):591-594
Web of Science PubMed FullText FullText_MUG

 

Kürtül, I; Hammer, N; Rabi, S; Saito, T; Böhme, J; Steinke, H Oblique sectional planes of block plastinates eased by Sac Plastination.
Ann Anat. 2012; 194(4):404-406
Web of Science PubMed FullText FullText_MUG

 

Rothstock, S; Plecko, M; Kloub, M; Schiuma, D; Windolf, M; Gueorguiev, B Biomechanical evaluation of two intramedullary nailing techniques with different locking options in a three-part fracture proximal humerus model.
Clin Biomech (Bristol, Avon). 2012; 27(7): 686-691.
Web of Science PubMed FullText FullText_MUG

 

Sadoghi, P; Schröder, C; Fottner, A; Steinbrück, A; Betz, O; Müller, PE; Jansson, V; Hölzer, A Application and survival curve of total hip arthroplasties: a systematic comparative analysis using worldwide hip arthroplasty registers.
Int Orthop. 2012; 36(11):2197-2203 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

2011

Pocivalnik, M; Pichler, G; Zotter, H; Tax, N; Müller, W; Urlesberger, B Regional tissue oxygen saturation: comparability and reproducibility of different devices.
J Biomed Opt. 2011; 16(5):057004-057004 [OPEN ACCESS]
Web of Science PubMed FullText FullText_MUG

 

2010

Cagran, C; Huber, P; Müller, W Dynamic force measurements for a high bar using 3D motion capturing.
J Biomech. 2010; 43(4): 767-770.
Web of Science PubMed FullText FullText_MUG

 

Faschinger, C; Mossböck, G Continuous 24 h monitoring of changes in intraocular pressure with the wireless contact lens sensor Triggerfish™. First results in patients].
Ophthalmologe. 2010; 107(10):918-922
Web of Science PubMed FullText FullText_MUG

 

Feichtner, F; Schaller, R; Fercher, A; Ratzer, M; Ellmerer, M; Plank, J; Krause, B; Pieber, T; Schaupp, L Microdialysis based device for continuous extravascular monitoring of blood glucose.
Biomed Microdevices. 2010; 12(3): 399-407.
Web of Science PubMed FullText FullText_MUG

 

Fischer, L; Tetzlaff, R; Schöbinger, M; Radeleff, B; Bruckner, T; Meinzer, HP; Büchler, MW; Schemmer, P How many CT detector rows are necessary to perform adequate three dimensional visualization?
Eur J Radiol. 2010; 74(3):e144-e148
Web of Science PubMed FullText FullText_MUG

 

Olipitz, W; Hembrador, S; Davidson, M; Yanch, JC; Engelward, BP Development and characterization of a novel variable low dose-rate irradiator for in vivo mouse studies.
Health Phys. 2010; 98(5):727-734 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Utzschneider, S; Harrasser, N; Sadoghi, P; Weber, P; Schröder, C; Pietschmann, MF; Jansson, V Crosslinked polyethylene in knee arthroplasty: a simulator study evaluating the positive influence on the tribocontact area in the fixed-bearing knee.
Arch Orthop Trauma Surg. 2010; 130(11):1419-1424
Web of Science PubMed FullText FullText_MUG

 

2009

Schaller, R; Feichtner, F; Köhler, H; Bodenlenz, M; Plank, J; Wutte, A; Mader, JK; Ellmerer, M; Hellmich, R; Wedig, H; Hainisch, R; Pieber, TR; Schaupp, L A novel automated discontinuous venous blood monitoring system for ex vivo glucose determination in humans.
Biosens Bioelectron. 2009; 24(7): 2239-2245.
Web of Science PubMed FullText FullText_MUG Google Scholar

 

2008

Morak, J; Schwetz, V; Hayn, D; Fruhwald, F; Schreier, G Electronic data capture platform for clinical research based on mobile phones and near field communication technology.
Conf Proc IEEE Eng Med Biol Soc. 2008; 2008: 5334-5337.
PubMed FullText FullText_MUG

 

2007

Wohlfart, C; Tschuschnig, K; Fellner, P; Weiss, K; Vidic, B; El-Shabrawi, Y; Ardjomand, N Visual function with blue light filter IOLs
Klin Monatsbl Augenheilkd. 2007; 224(1): 23-27.
Web of Science PubMed FullText FullText_MUG

 

2005

Langmann, G; Lechner, H; Wenzel, E; Mossböck, G; Wackernagel, W Transpupillary thermotherapy (TTT) for uveal melanomas. Long term results of a single TTT with an adapter for a conventional infrared laser].
Ophthalmologe. 2005; 102(12):1162-1167
Web of Science PubMed FullText FullText_MUG

 

Schicho, K; Figl, M; Donat, M; Birkfellner, W; Seemann, R; Wagner, A; Bergmann, H; Ewers, R Stability of miniature electromagnetic tracking systems.
Phys Med Biol. 2005; 50(9): 2089-2098.
Web of Science PubMed FullText FullText_MUG

 

2004

Martinovic, I; Farah, I; Everlien, M; Knez, I; Greve, HP; Vogt, P Aortic valve replacement with the Cryolife-O'Brien stentless aortic bioprosthesis: five-year experience.
J Cardiovasc Surg (Torino). 2004; 45(6):557-563
Web of Science PubMed

 

2003

Aigner, C; Pechmann, M; Stacher, R; Rehak, P; Windhager, R Measurement precision of sonography to evaluate movable meniscal bearings
Orthopade. 2003; 32(4):282-286
Web of Science PubMed FullText FullText_MUG

 

Winkler, P; Bergmann, H; Stuecklschweiger, G; Guss, H Introducing a system for automated control of rotation axes, collimator and laser adjustment for a medical linear accelerator.
Phys Med Biol. 2003; 48(9):1123-1132
Web of Science PubMed FullText FullText_MUG

 

2000

Anelli-Monti, M; Mächler, H; Oberwalder, O; Knez, I; Dacar, D; Rigler, B Lead stability in long-term follow-up of bipolar leads].
Wien Med Wochenschr. 2000; 150(19-21):414-418
PubMed

 

© Med Uni Graz Impressum