Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Birkl, C; Soellradl, M; Toeglhofer, AM; Krassnig, S; Leoni, M; Pirpamer, L; Vorauer, T; Krenn, H; Haybaeck, J; Fazekas, F; Ropele, S; Langkammer, C.
Effects of concentration and vendor specific composition of formalin on postmortem MRI of the human brain.
Magn Reson Med. 2018; 79(2):1111-1115 Doi: 10.1002/mrm.26699 [OPEN ACCESS]
Web of Science PubMed FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Birkl Christoph
Co-Autor*innen der Med Uni Graz
Birkl-Töglhofer Anna Maria
Fazekas Franz
Haybäck Johannes
Kraßnig Stefanie
Langkammer Christian
Leoni Marlene
Pirpamer Lukas
Ropele Stefan
Söllradl Martin
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
Formalin fixation prevents tissue autolysis by crosslinking proteins and changes tissue microstructure and MRI signal characteristics. Previous studies showed high variations in MR relaxation time constants of formalin fixed brain tissue, which has been attributed to the use of different formalin concentrations. Our investigations confirmed the influence of formalin concentration on relaxation times and unexpectedly revealed an influence of vendor specific formalin composition, which has not been investigated so far. We systematically analyzed relaxation times of human brain tissue fixed with 4% and 10% formalin compared with unfixed condition at 3 Tesla MRI. Furthermore, we assessed relaxation times of nine formalin solutions from different vendors and performed comparisons of their magnetic susceptibility by SQUID (superconducting quantum interference device) magnetometry. Tissue relaxation times decreased approximately twice as fast using 10% than in 4% formalin fixation. The vendor specific composition of the formalin solutions and concentration dependent paramagnetic effects showed a substantial contribution to differences in relaxation times of formalin. Our study demonstrates that differences of the formalin composition have substantial effects on MRI signal characteristics after fixation, which can explain the divergence of reported relaxation times beyond the effect of differences in formalin concentration. Magn Reson Med 79:1111-1115, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

Find related publications in this database (Keywords)
formalin fixation
formalin concentration
postmortem MRI
formalin fixed brain tissue
relaxation properties of formalin
magnetic properties of formalin
© Med Uni Graz Impressum