Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Gupta, D; Vijgen, J; Potter, T; Scherr, D; Van, Herendael, H; Knecht, S; Kobza, R; Berte, B; Sandgaard, N; Albenque, JP; Széplaki, G; Stevenhagen, Y; Taghji, P; Wright, M; Duytschaever, M.
Quality of life and healthcare utilisation improvements after atrial fibrillation ablation.
Heart. 2021; 107(16):1296-1302 Doi: 10.1136/heartjnl-2020-318676 [OPEN ACCESS]
Web of Science PubMed PUBMED Central FullText FullText_MUG

 

Co-Autor*innen der Med Uni Graz
Scherr Daniel
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
OBJECTIVE: Pulmonary vein isolation (PVI) guided by a standardised CLOSE (contiguous optimised lesions) protocol has been shown to increase clinical success after catheter ablation for paroxysmal atrial fibrillation (PAF). This study analysed healthcare utilisation and quality of life (QOL) outcomes from a large multicentre prospective study, measured association between QOL and atrial fibrillation (AF) burden and identified factors associated with lack of QOL improvement. METHODS: CLOSE-guided ablation was performed in 329 consecutive patients (age 61.4 years, 60.8% male) with drug-refractory PAF in 17 European centres. QOL was measured at baseline and 12 months post-ablation via Atrial Fibrillation Effect on QualiTy of Life Survey (AFEQT) and EuroQoL EQ-5D-5L questionnaires. All-cause and cardiovascular hospitalisations and cardioversions over 12 months pre-ablation and post-ablation were recorded. Rhythm monitoring included weekly and symptom-driven trans-telephonic monitoring, plus ECG and Holter monitoring at 3, 6 and 12 months. AF burden was defined as the percentage of postblanking tracings with an atrial tachyarrhythmia ≥30 s. Continuous measures across multiple time points were analysed using paired t-tests, and associations between various continuous measures were analysed using independent sample t-tests. Each statistical test used two-sided p values with a significance level of 0.05. RESULTS: Both QOL instruments showed significant 12-month improvements across all domains: AFEQT score increased 25.1-37.5 points and 33.3%-50.8% fewer patients reporting any problem across EuroQoL EQ-5D-5L domains. Overall, AFEQT improvement was highly associated with AF burden (p=0.009 for <10% vs ≥10% burden, p<0.001 for <20% vs ≥20% burden). Cardiovascular hospitalisations were significantly decreased after ablation (42%, p=0.001). Patients without substantial improvement in AFEQT (55/301, 18.2%) had higher AFEQT and CHA2DS2-VASc scores at baseline, and higher AF burden following PVI. CONCLUSIONS: QOL improved and healthcare utilisation decreased significantly after ablation with a standardised CLOSE protocol. QOL improvement was significantly associated with impairment at baseline and AF burden after ablation. TRIAL REGISTRATION NUMBER: NCT03062046.
Find related publications in this database (using NLM MeSH Indexing)
Atrial Fibrillation - diagnosis, epidemiology, psychology, surgery
Catheter Ablation - adverse effects, methods
Cost of Illness - administration & dosage
Electric Countershock - statistics & numerical data
Electrocardiography, Ambulatory - methods, statistics & numerical data
Europe - epidemiology
Female - administration & dosage
Hospitalization - statistics & numerical data
Humans - administration & dosage
Male - administration & dosage
Middle Aged - administration & dosage
Outcome Assessment, Health Care - administration & dosage
Patient Acceptance of Health Care - statistics & numerical data
Perioperative Period - psychology, statistics & numerical data
Pulmonary Veins - surgery
Quality of Life - administration & dosage
Surveys and Questionnaires - administration & dosage

Find related publications in this database (Keywords)
atrial fibrillation
catheter ablation
© Med Uni Graz Impressum