Pichler, G; Grossauer, K; Peichl, E; Gaster, A; Berghold, A; Schwantzer, G; Zotter, H; Müller, W; Urlesberger, B.
Combination of different noninvasive measuring techniques: a new approach to increase accuracy of peripheral near infrared spectroscopy.
J Biomed Opt. 2009; 14(1): 014014-014014. Doi: 10.1117/1.3076193
Web of Science PubMed FullText FullText_MUG Google Scholar

 

Führende Autor*innen der Med Uni Graz
Pichler Gerhard
Co-Autor*innen der Med Uni Graz
Berghold Andrea
Großauer Karin
Müller Wilhelm
Schwantzer Gerold
Urlesberger Berndt
Zotter Heinz
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
One of the problems of near-infrared-spectroscopy (NIRS) measurements is low reproducibility. The aim of the present study was to introduce quality criteria to increase reproducibility of peripheral NIRS measurements. In a prospective cohort study in 40 neonates, repeated NIRS measurements were performed on the calf. During five "reapplication" periods (of NIRS optodes), five "measurements" (venous occlusions) were performed. Tissue oxygenation index (TOI), mixed venous oxygenation (SvO2), fractional oxygen extraction (FOE), hemoglobin flow (Hbflow), oxygen delivery (DO2), and oxygen consumption (VO2) were assessed. Measurements with linear changes during venous occlusions were included for further analysis (first quality criterion: R(2)>0.95). The second quality criterion was the equation 0 < or = TOI-SvO2 < or = (SaO2-SvO2)x0.2. Variance components and mean standard deviations were analyzed after introduction of the quality criteria. Variance components of reapplication and measurement decreased after introduction of the second quality criterion (TOI: 46.6-35.0%, SvO2: 76.8-38.2%, FOE: 73.1-37.5%, Hbflow: 70.3-51.9%, DO2: 71.5-52.7%, and VO2: 70.9-63.8%). Mean standard deviations of TOI (6.6+/-3.0 to 4.7+/-3.2%), SvO2 (11.1+/-4.8 to 5.7+/-3.9%), FOE (11.3+/-4.8 to 5.9+/-4.0%), Hbflow (4.3+/-2.0 to 2.9+/-1.6 micromol100 mLmin), and DO2 (17.8+/-7.6 to 11.4+/-6.2 micromol100 mLmin) decreased significantly, too. Only 12% of measurements fulfilled both quality criteria. With the introduction of two quality criteria, test-retest variability of peripheral NIRS measurements decreased significantly and reproducibility increased significantly.
Find related publications in this database (using NLM MeSH Indexing)
Algorithms -
Diagnosis, Computer-Assisted - methods
Female -
Humans -
Infant, Newborn -
Male -
Muscle, Skeletal - blood supply
Oximetry - methods
Oxygen - analysis
Reproducibility of Results -
Sensitivity and Specificity -
Spectroscopy, Near-Infrared - methods

Find related publications in this database (Keywords)
near-infrared spectroscopy
peripheral muscle
reproducibility
quality criteria