Medizinische Universität Graz Austria/Österreich - Forschungsportal - Medical University of Graz

Logo MUG-Forschungsportal

Gewählte Publikation:

SHR Neuro Krebs Kardio Lipid Stoffw Microb

Bohlsen, D; Talakic, E; Fritz, GA; Quehenberger, F; Tillich, M; Schoellnast, H.
First pass dual input volume CT-perfusion of lung lesions: The influence of the CT- value range settings on the perfusion values of benign and malignant entities.
Eur J Radiol. 2016; 85(6):1109-14 Doi: 10.1016/j.ejrad.2016.03.013
Web of Science PubMed FullText FullText_MUG

 

Führende Autor*innen der Med Uni Graz
Bohlsen Dennis
Schoellnast Helmut
Co-Autor*innen der Med Uni Graz
Fritz Gerald
Quehenberger Franz
Talakic Emina
Altmetrics:

Dimensions Citations:

Plum Analytics:

Scite (citation analytics):

Abstract:
OBJECTIVE: To assess the influence of the lower threshold for segmentation of the volume of interest on the perfusion values in first-pass dual input volume CT-perfusion of lung lesions. MATERIALS AND METHODS: Dual input maximum slope volume CT-perfusion was performed in 48 patients (mean age±standard deviation [SD], 68±10years; range, 46-87 years) who underwent subsequent CT-guided biopsy to evaluate a lung lesion. Using commercial perfusion software, a lower and upper threshold was set for determination of the CT-value range, which again determined the volume of interest for perfusion calculation. The pulmonary arterial flow (PAF), bronchial arterial flow (BAF), and perfusion index (PI; PAF/(PAF+BAF)) were calculated at following pre contrast CT value range settings: -80 to 150HU (setting 1), -200 to 150HU (setting 2), -300 to 150HU (setting 3), and -500 to 150HU (setting 4). Perfusion parameters were compared between benign (n, 15) and malignant (n, 33) lesions for each setting. Intraobserver- and interobserver reliability were calculated for setting 4. RESULTS: Median PAF was significantly higher in malignant lesions than in benign lesions for all settings (53-96 versus 29-62mL/min/100mL, P<0.05). There was no significant difference in BAF between malignant and benign lesions. Median PAF of all lesions was significantly influenced by the CT value range setting (P<0.05), whereas the values increased from setting 1 to 4. Intraobserver analysis as well as interobserver analysis of PAF at setting 4 showed excellent reliability (Cronbach's alpha 0.98 and 0.95, respectively, P<0.01). CONCLUSION: PAF derived from first-pass dual-input maximum slope volume CT perfusion is statistically significantly higher in malignant than in benign lesion, whereas the measurements are influenced by the lower threshold of the CT value range setting. This has to be considered when using cutoff values provided in the literature for differentiation between benign and malignant lung lesions.
Find related publications in this database (using NLM MeSH Indexing)
Adenocarcinoma - blood supply, diagnostic imaging
Aged - administration & dosage
Aged, 80 and over - administration & dosage
Bronchial Arteries - diagnostic imaging
Cone-Beam Computed Tomography - statistics & numerical data
Contrast Media - administration & dosage
Female - administration & dosage
Humans - administration & dosage
Image Processing, Computer-Assisted - statistics & numerical data
Image-Guided Biopsy - methods
Iopamidol - administration & dosage, analogs & derivatives
Lung - diagnostic imaging
Lung Neoplasms - blood supply, diagnostic imaging
Male - administration & dosage
Middle Aged - administration & dosage
Observer Variation - administration & dosage
Prospective Studies - administration & dosage
Pulmonary Artery - diagnostic imaging
Pulmonary Circulation - physiology
Regional Blood Flow - physiology
Reproducibility of Results - administration & dosage
Software - administration & dosage
Solitary Pulmonary Nodule - diagnostic imaging

Find related publications in this database (Keywords)
Lung neoplasms
Volume computed tomography
Perfusion
© Med Uni Graz Impressum